Part Number Hot Search : 
00EL01 HSBD438 2SC4303 25C256 HD74LS09 AN78N06 LPC2368F X9241USI
Product Description
Full Text Search
 

To Download AQF120U-180W-16 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. aqf120u-5s aqf120u-12s aqf120u-15s aqf120u-24s aqf120u-48s max output wattage (w) 150 w (30cfm fan) 180 w (18cfm fan) max output wattage (w) 120 w voltage 90-264 vac or 120-370 vdc (80-274 vac or 110-390 vdc with derating) frequency (hz) 47-63 hz current (full load) <2.0 a max. (115 vac) / <1.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 0.5 ma max. input power factor pf>0.99 (115 vac) / pf>0.95 (230 vac) at full load voltage (v.dc.) 5v 12v 15v 24v 48v voltage accuracy 2% voltage adj. range (v.dc) 4.7~5.3v 11.4~13.2v 13.5~16v 22.8~26.4v 45.6~52v current (18/30 cfm fan)(a) max 0~30 (30cfm fan) 0~15 (18cfm fan) 0~12 (18cfm fan) 0~7.5 (18cfm fan) 0~3.75 (18cfm fan) current (convection) (a) max 0~24 0~10 0~8 0~5 0~2.5 line regulation 1% load regulation 1% minimum load 5% 1% maximum capacitive load 100,000 f 40,000f 35,000f 20,000f 1,200f ripple & noise (max.) 100mv 50mv 50mv 100mv 200mv efficiency (typ.) 87% 90% 90% 93% 93% output hold-up time 15 ms min. over power protection auto recovery over voltage protection auto recovery ( > 125% vout) protection short circuit protection auto recovery input-output (v.ac) 4000vac or 5656vdc input-fg (v.ac) 2000v isolation output-fg . (v.ac) 500v operating temperature -25c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >120,000 h @ 25c (mil-hdbk-217f, notice 1) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. dimension (l x w x h) 5.0 x 3.24 x 1.5 inches ( 127.0 x 82.2 x 38.1 mm ) tolerance ? 0.5 mm weight 382 g physical cooling method free convection / 18 cfm fan safety agency approvals ce, ul60950-1(exc ept 5s / 15s), cb(except 5s / 15s) emi (conducted & radiated emission) en61000-6-3 en 55022 class b emc ems (noise immunity) en 55024 key features ? u bracket switching power supply ? 180 watt with 18cfm fan for 12v to 48v output voltage ? 150 watt with 30cfm fan for 5v output voltage ? high efficiency up to 93% ? universal input: 90-264 vac ? low ripple and noise ? with p.f.c. function >0.95 ? 120 watt with free air convection ? ultra compact size: 5.0 x 3.24 x 1.5 inches ? 3-year product warranty a type (except 5s) b type (except 5s)
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. hold-up time measured at 90% vout. 3. strongly recommend to conduct this test with dc voltage. if customer wishes to test with ac voltage, please disconnect all y-capacitors within arch power supply. derating block diagram
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ( top view ) standard (5s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 +dc out 5 -dc out assembly instructions *u case t=2.0mm customer is advised to screw into the threads no more than 2.0mm
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- mechanical dimension ( top view ) standard (12s 15s 24s 48s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 +dc out 5 +dc out 6 -dc out 7 -dc out a type (except 5s) b type (except 5s) pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 ~ 7 +dc out 8 ~ 11 -dc out pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 ~ 5 +dc out 6 ~ 7 -dc out assembly instructions *u case t=2.0mm customer is advised to screw into the threads no more than 2.0mm
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load aqf120u-5s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 85.37 86.17 87.46 87.76 88.14 load (%) 10 20 30 40 50 115v (%) 69.59 81.53 83.15 84.92 85.96 230v (%) 73.66 81.49 85.04 86.21 87.16 load (%) 60 70 80 90 100 115v (%) 86.44 86.45 86.37 86.48 86.20 230v (%) 87.57 87.75 87.98 87.94 87.80 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v180v230v264v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf120u-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.45 89.96 92 92.77 92.3 load (%) 10 20 30 40 50 115v (%) 73.62 82.98 86.43 88.26 89.27 230v (%) 71.83 81.82 86.81 89.54 90.58 load (%) 60 70 80 90 100 115v (%) 89.72 89.95 90.11 90.1 89.96 230v (%) 91.74 92.18 92.53 92.62 92.77 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -6- efficiency versus load aqf120u-15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.03 88.78 90.06 90.45 90.75 load (%) 10 20 30 40 50 115v (%) 67.05 78.17 82.74 85.07 85.52 230v (%) 67.05 77.17 82.17 84.61 86.14 load (%) 60 70 80 90 100 115v (%) 87.40 88.34 88.44 88.67 88.78 230v (%) 87.39 88.68 89.5 90.14 90.45 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% aqf120u-24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.78 91.27 93.11 93.52 93.81 load (%) 10 20 30 40 50 115v (%) 71.89 82.79 86.97 88.9 89.82 230v (%) 72.3 84.22 88.46 89.21 92.29 load (%) 60 70 80 90 100 115v (%) 90.54 90.78 91.13 91.4 91.27 230v (%) 92.14 92.86 93.14 93.44 93.52 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : c_5 update : 2015.11.17 ac-dc switching power supply aqf120u series 180 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -7- efficiency versus load aqf120u-48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.56 91.86 93.20 93.76 93.61 load (%) 10 20 30 40 50 115v (%) 74.99 83.9 87.25 89.17 90.01 230v (%) 67.31 79.29 84.97 88.18 89.99 load (%) 60 70 80 90 100 115v (%) 90.69 91.18 91.46 91.84 91.86 230v (%) 91.24 92.15 92.84 93.36 93.76 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 100.00% 90v 115v 180v 230v 264v vin eff% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%


▲Up To Search▲   

 
Price & Availability of AQF120U-180W-16

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X